Electrical Testing Nottingham

Electrical Testing Nottingham

All the Electrical Testing Services you require, throughout Nottingham

Exceptional Electrical Testing Services throughout Nottingham

Electrical Testing Nottingham a offer professional and efficient electrical compliance services to companies within all sectors.


We understand what form of electrical testing is required and work around your schedule to ensure there is minimum disruption to your business to suit your individual needs and requirements, at no extra cost.


As approved inspection and testing contractors, CSE can offer your establishment, a frequent and reliable Electrical Testing Service ensuring you stay up to date with the latest Legal Requirements in accordance with BS 7671:01925320707 regulations.



Commercial Electrical Compliance, servicing all sectors

Our highly qualified team of electrical engineers undertake all types of Electrical Testing on every scale, across all industries throughout Nottingham.


Emergency lighting testing services can also be included in our electrical maintenance contracts, electrical installation and electrical repairs for clients wishing to outsource their electrical works.


So, whatever your requirements are, we can help, call 01925320707 or send your enquiry to info@cseelectrical.co.uk


All Services

Electrical Testing Sequence

To comply with electrical safety standards under law, inspection and testing procedures should be performed on all non-domestic electrical installations. The electrical testing sequence will be determined primarily by whether testing is for initial verification of a new installation or periodic testing of an existing appliance.


Initial Verification Testing Sequence

New installations and alterations require ‘Initial Verification’. This involves a specific electrical testing sequence to be followed. Each test builds on the previous one having passed, to give correct results without the test causing danger.


Under BS 7671, reg. 612.1, tests A to G are, where relevant, to be carried out first and in order before the installation is energised:


  • Earthing and bonding satisfactory
  • All conductors present and continuous
  • Insulation satisfactory
  • No short circuits or excessive leakage
  • Polarity/connection of all items correct
  • Resistance of any earth electrodes sufficiently low
  • Insulation resistance test should be the last test done, and all equipment covers should be replaced, save for the cover of the distribution board, prior to re-energising.


Under regulation 612.1, tests I to O do not necessarily have to be conducted in a particular order, but IEE Guidance Note 3 stipulates all the tests to be conducted in the order above.


Following this order should in most cases help to ensure satisfactory results in one test will normally indicate that the following test can be carried out effectively, minimising the amount of retesting. In practice, however, the order may need to be varied for example to minimise disruption.


An experienced and qualified electrician will be able to assess and advise on the most appropriate testing sequence.


Fixed Wire Electrical Testing 

Electrical Testing Nottingham
Electrical testing is a vital procedure to ensure the safety of employees, customers and tenants.
All electrical installations deteriorate with age and use. They should therefore be electrical tested inspected at regular intervals to keep checking whether they are in a satisfactory condition for continued use. Such safety tests are commonly referred to as 'periodic inspection and testing'. 
Periodic inspection and testing should only be carried out by electrically competent persons, such as registered electricians. 

They will check the condition of the electrics against the UK standard for the safety of electrical installations.
Checking our electrical appliances are in full working service keeps us compliant with many Health and Safety regulations, such as “The health and safety at work Act 1974”.
Visual checks of our electrical equipment should be conducted frequently, any damage to wiring should be repaired by a person with the necessary skills, knowledge and experience to process this work safely, CSE can provide this to ease your mind.

We need to be aware that a wide range of voltages can be dangerous for different reasons. Low voltages can produce enough of a spark to ignite an explosion, CSE can ensure that your electrical equipment is fit for purpose and safe for all to use.

An initial verification inspection and survey will reveal if any circuits or electrical equipment are being overloaded, locate any potential electrical shock risks and fire hazards in an installation, identify any defective DIY electrical work, or highlight any lack of earthing or bonding.

Once completed you will be issued with an Electrical Condition Report (EICR).


An EICR, should only by carried out by a fully qualified and competent electrician. Once the report has been completed, the installer will issue a certificate on software which is recognised by our governing body NAPIT.

CSE charge a fixed price per circuit. Please note that we do charge 3 phase circuits as 3 single circuits.

Fixed Wire Electrical Testing Requirements

Portable Appliance Electrical Testing 

Electrical Testing Nottingham
A portable appliance electrical portable appliance electrical testing is a routine inspection of some types of electrical appliance to check they are safe to use. Its purpose is to prevent electrical accidents in the workplace.
A full portable appliance electrical test should include both a visual inspection and a more in-depth check using specialist portable appliance electrical testing equipment. This test includes earth continuity, lead polarity, and insulation resistance checks.

Some appliances only need a reduced test, called a portable appliance electrical testing insulation test.

At the end of a portable appliance electrical test, every appliance should be marked ‘passed’ or ‘failed’. Ideally there should be a record of the results.
The following items require portable appliance electrical testing:
  •  Fixed appliances
  • Stationary appliances
  • IT appliances
  • Moveable appliances
  • Portable appliances
  • Cables and chargers
  • Hand Held appliances
Health and Safety at Work etc. Act 1974

So, Why should you choose CSE?

CSE offer a wide range of Electrical Testing Services throughout London, upon commercial and industrial properties offering a  reliable and undisruptive service.


As approved inspection and testing contractors, CSE offer your establishment, a frequent and reliable Fixed Wire Testing Service ensuring you stay up to date with the latest Legal Requirements in accordance with BS 7671:01925 320 707 regulations.


Our team of electrical engineers undertake Electrical Testing on every scale, across all industries and on a nationwide basis. So, whatever your requirements are, we can help.


Regardless of size or market sector, we have the capability to provide innovative electrical services throughout the UK. From single sites to large national property portfolios.  We offer the most expert, cost-effective, and hassle-free electrical services to keep businesses safe and compliant.
 

Our innovative use of technology and online reporting means we can provide full photographic records of our inspections, making our reports user friendly and easy to understand. 

Testing Offers and Package Deals throughout Nottingham


We will beat any like for like quote.

10%



3 year or 5 year contracts to suit your needs, we can do this for all our services and guarantee the best price. 

Contact us
Electrical Testing Nottingham

Fast Service

Next day Commercial 5 year EICR test Service

Electrical Testing Nottingham

Competitive Rates

Commercial EICR electrical testing inspections from £6.00 per circuit

Electrical Testing Nottingham

Quick Turnaround

Receive a satisfactory report within 10 workings days

Reliable Electrical Testing throughout Nottingham. We offer a reliable, transparent electrical testing service to all commercial properties.

Booking in your electrical test is simple, and we pride ourselves on delivering a smooth non-interrupted service. 


OUR! 3 Easy Steps to Receive a Satisfactory Report
Electrical Testing Nottingham

TEST

An experienced and qualified electrician will conduct a visual and live inspection upon each circuit.  All findings will be recorded.

Electrical Testing Nottingham

REPORT

2 working days after inspection you will receive your EICR (report) list any faults which will require correcting.

Electrical Testing Nottingham

CORRECTIVE WORKS

CSE will automatically create you a quotation for any corrective works, meaning you can book in immediately.

Request a Quote

Please complete the form below to obtain your free quotation

Contact Us

Electrical Testing Nottingham
FREE SITE SURVEYS
REPORT SENT WITHIN 3 WORKING DAYS
FREE ACCESS TO REPORTS ONLINE
Electrical Testing London
Share by: